RAD-69: SOAP Retrieve for Single Image Study
Purpose / Context
The Imaging Document Source has submitted a KOS for a study with a
single image. In this test, we retrieve the single image using a
SOAP retrieve.
Instructions
- Complete the instructions listed in test ids_2018-4801a. This
will register the proper KOS object with the testing system.
Assuming test ids_2018-4801a has completed successfully, you do
not need to submit the data a second time.
- Make sure that the image data for patient
IDS_2018-4801a^^^&1.3.6.1.4.1.21367.2005.13.20.1000&ISO
is in your system and ready for a WADO retrieve.
- Activate the test button to initiate the SOAP retrieve and
validation steps.
Notes
Validation
The test software provides the following validation tests:
- SOAP response is properly formatted.
- SOAP response contains proper content
- Repository Unique Id
- Document Unique ID (DICOM SOP Instance UID)
- DICOM image is returned in SOAP response
- Original DICOM values in image remain unchanged
- Patient ID, Birth Date, Sex
- Study Instance UID
- Series Intance UID
- SOP Instance UID