Transfer Syntax Failure, Single Responding Gateway

Tests the ability of the Initiating Imaging Gateway actor (SUT) to respond correctly to Retrieve Image Document Set (RAD-69) Request from an Image Document Consumer actor (Simulator), for a single DICOM image file using the JPEG Baseline (Process 1) (1.2.840.10008.1.2.4.50) Transfer Syntax, in the case where the Image Document Source is not able to return the image file in that Syntax.

Retrieve Parameters

RIG Home Community ID (A) urn:oid:1.3.6.1.4.1.21367.13.70.101
IDS Repository Unique ID (A1) 1.3.6.1.4.1.21367.13.71.101
Transfer Syntax UID 1.2.840.10008.1.2.4.50

Note: Although the test environment provides for three Responding Imaging Gateways and multiple Image Document Sources, this test expects a single image to be returned from a single Responding Imaging Gateway (A) and a single Imaging Document Source (A1) behind that gateway.

Test Execution

The test consists of three steps:

  1. Test software sends RAD-69 request to System Under test and records response.
  2. Test software validates the RAD-75 request that is sent by the System Under Test.
  3. Test software validates the RAD-69 response sent by the System Under Test.